Please use this identifier to cite or link to this item: https://geoscience.nt.gov.au/gemis/ntgsjspui/handle/1/71661
Export to Endnote
Title: Round Robin results on Coronation Hill Samples June 1987.
Title Holder / Company: BHP Minerals
Coronation Hill Joint Venture
Report id: CR1987-0326
Tenure: MLN27 MLN23 MLN28 MLN26
Year: 1987
Author: Bumstead, ED
Abstract: The report presents the results of a round robin survey using 31 samples and four reference standards from Coronation Hill to six laboratories. It is concluded that all laboratories carried out acceptable gold and palladium analysis. The lab in use for routine Coronation Hill assays was found to be giving low values for platinum. Results for Pt show high variability at all laboratories. There was some indication of inhomogeneity, particularly in Au. CSIRO has done some experimental analysis using particle induced X-ray emission (PIXE) which gave indications of 3.5g/t Ru, 0.5g/t Rh and 2g/t Ir in reference materials made from Coronation Hill material. The report contains a good discussion of analytical procedures and potential problems in analysis of Pt group metals.
Date Added: 23-Oct-2013
Appears in Collections:Minerals Exploration Reports (MEX)

Files in this Report:
File SizeFormat Add to
Download
CR19870326.pdf1.53 MBPDF Add


Items in GEMIS are protected by copyright unless otherwise indicated.