H0002 Version 4 H0003 Date_generated 11-Nov-24 H0004 Reporting_period_end_date 22-Aug-24 H0005 State NT H0100 Tenement_no/Combind_report_no EL33008 H0101 Tenement_holder URO Corporation H0102 Project_name EL33008 H0106 Tenement_operator URO Corporation H0150 250K_map_sheet_number SF5313 H0151 100K_map_sheet_number 5351 5451 H0152 50K_map_sheet_number H0153 25K_map_sheet_number H0200 Start_date_of_data_acquisition 5-Aug-22 H0201 End_date_of_data_acquisition 22-Aug-24 H0202 Data_format SG4 H0203 Number_of_data_records 3 H0204 Date_of_metadata_update 11-Nov-24 H0305 SurfGeochem_Data_File EL33008_2024_P_02_SurfaceGeochemPXRF.txt EL33008_2024_P_03_SurfaceGeochemAssay.txt H0308 File verification List EL33008_2024_P_04_FileListing.txt H0319 SURFQAQC_data_file H0500 Feature_located Surface Sample H0501 Geodetic_datum GDA94 H0502 Vertical_datum AHD H0503 Projection Universal Transverse Mercator (UTM) H0508 Local Grid Name H0530 Coordinate_system Projected H0531 Projection_zone 53 H0532 Surface_location_Survey_Instrument GPS H0533 Surface_Location_Survey_Company URO Corporation H0538 Surface_Geophysical_Survey_Instrument H0539 Surface_Geophysical_Survey_Company H0600 Sample_Code Soil Rock H0601 Sample_Type Soil Rock H0602 Sample_description soil samples Rock Chip samples H0700 Sample_Prep_Code Intertek Genalysis Gekko H0701 Sample_Prep_Desc Dry - crush 2mm pulverise up to 3kg. 0.3g of sample weight needs to be digested with the 4mL of AquaRegia solution for 25min at 85-90°C and made up to the 20mL final volume with the DI Water H0702 Job_no 6.3/2300563 GAL 230667 H0800 Assay_code AR1/MS Q2300 Q2450 H0801 Assay_company Intertek Genalysis Gekko Gekko H0802 Assay_description 1g Aqua-Regia digest. Analysed by Inductively Coupled Plasma Mass Spectrometry. Fire Assay -Fusion of the sample with suitable fluxing agents and Lead at 1100°C - lead then removed by cupellation at 950°C. Precious metal prill digested with an Aqua Regia and solution analysed by Atomic Absorption Spectrometry. Multi-element acid-digest ICP H0900 Remarks Assay results of surface sampling H1000 Sample ID Easting_MGA Northing_MGA Sample Type Elevation Grid Assay_Company Assay_Code Job_Number Dy Er Eu Gd Ho Lu Nd Pr Sm Tb Tm Yb Au Ag As Ba Be Bi Ca Cd Co Cr Cu Fe K Mg Mn Mo Na Ni P Pb Sb Th Ti U V W Zn H1001 NA metres metres NA metres NA NA NA NA ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm NA ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm NA ppm ppm ppm ppm ppm ppm ppm ppm ppm ppm H1002 AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS AR1/MS Q2300 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 Q2450 H1003 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.005 0.04 10 100 10 10 10 100 10 10 10 10 100 100 100 100 10 100 10 100 100 10 100 100 100 10 100 10 H1004 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 H1005 H1006 H1007 Intertek Intertek Intertek Intertek Intertek Intertek Intertek Intertek Intertek Intertek Intertek Intertek Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko Gekko D URX00700 238387 7433298 Soil NA GDA94/53 Intertek Genalysis AR1/MS 6.3/2300563 5.485 2.652 1.208 6.461 0.953 0.32 40.787 11.376 7.628 0.938 0.33 2.165 D URX00464 251660 7429173 Soil NA GDA94/53 Intertek Genalysis AR1/MS 6.3/2300563 0.81 0.28 0.164 1.477 0.121 0.03 10.98 3.173 2.018 0.171 0.031 0.212 D US0009C 256149 7430601 Rock NA GDA94/53 Gekko Digest ICP GAL 230667 <0.04 11.5 <10 4512 <10 <10 >50000 <10 <10 24.46 14.07 1253 787.4 >50000 21.09 <10 428.4 <10 255.7 <100 55.53 <100 <100 <100 22.68 <100 <10 EOF